Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial

Product Details
Customization: Available
After-sales Service: Global Warranty or Factory Warranty
Warranty: 1 Year
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001
  • Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial
  • Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial
  • Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial
  • Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial
  • Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial
  • Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial
Find Similar Products

Basic Info.

Model NO.
SMG-80
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
HSS
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Ordinary
Excitation Mode
AC Rotating Exciter
Frequency
50Hz or 60Hz
Voltage
208V-480V
Transport Package
Foam
Specification
80kVA
Trademark
VSD
Origin
China
HS Code
8502131000
Production Capacity
500PCS/Month

Product Description

Established 2015, VSD POWER Dedicating to provide the most efficiency Power Generator sets for Industrial, Commercial, 


Power range:  7KVA to 3000KVA;
Noise Level : (58DB-72DB @1m away);
Freuqency: 50HZ and 60HZ;


1000 mbar, 25ºC, 30% relative humidity. Power according to ISO 3046 normative.
 
Prime Power (PRP):
According to ISO 8528-1:2005, Prime power is the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output (Ppp) over 24 h of operation shall not exceed 70 % of the PRP.
 
Emergency Standby Power (ESP):
According to ISO 8528-1:2005, Emergency standby power is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed  70 % of the ESP
 
Genset Specification Engine Specification Dimensions LxWxH (mm) Weight (Kg)
Model Standby Prime Engine Model Mitsubishi gover-nor Cylind-ers Displace -ment (L) Fuel Con. 100% (L/H) Lube Capacity (L) Open Type Silent Canopy Open Type Silent Canopy
kVA kW kVA kW
SMG-9 9 7 8 6.4 L3E-65SAG M 3L 1.0 1.6 4 1300x650x950 1650x800x1050 425 760
SMG-12 12 10 11 9 S3L2-65SAG M 3L 1.3 2.6 4 1350x650x980 1750x800x1100 496 830
SMG-17 17 13 15 12 S4L2-65SAG M 4L 1.8 3.6 6 1350x650x980 1750x800x1100 510 845
SMG-25 25 20 23 18 S4Q2-65SAG M 4L 2.5 5.2 7 1600x650x1055 2200x850x1200 700 1070
SMG-35 35 28 32 25 S4S-65SAG M 4L 3.3 7.0 10 1650x750x1280 2240x1050x1376 780 1270
SMG-44 44 35 40 32 S4S-DT65SAG M 4L 3.3 9.4 10 1650x750x1280 2440x1133x1376 855 1375
SMG-55 55 44 50 40 S4K-D65SAG M 4L 4.2 11.5 13 1650x750x1280 2440x1133x1376 887 1407
SMG-66 66 53 60 48 S4K-DT65SAG M 4L 4.2 13.8 13 1650x750x1280 2440x1133x1376 908 1434
SMG-80 80 64 73 58 S6K-D65SAG M 6L 6.4 16.6 21 1750x850x1300 2440x1133x1376 1037 1560
SMG-100 100 80 90 72 S6K-DT65SAG M 6L 6.4 20.5 21 2240x850x1320 2700x1133x1666 1175 1735
SMG-715 715 572 650 520 S6R2-PTA-C E 6L 30.0 139.0 92 3525x1550x2030 4800x1800x2370 4170 6730
SMG-825 825 660 750 600 S6R2-PTAA-C E 6L 30.0 170.0 92 3525x1550x2030 4800x1800x2370 4220 6780
SMG-1375 1375 1100 1250 1000 S12R-PTA-C E 12V 49.0 266.0 180 4200x1805x2245 6058x2438x2591 7310 11370
SMG-1513 1513 1210 1375 1100 S12R-PTA2-C E 12V 49.0 281.0 180 4200x1805x2245 6058x2438x2591 7410 11470
SMG-1650 1650 1320 1500 1200 S12R-PTAA2-C E 12V 49.0 308.0 180 4200x1805x2245 6058x2438x2591 7360 11420
SMG-1876 1876 1500 1705 1364 S16R-PTA-C E 16V 65.4 310.0 230 5200x2260x2510 12192x2438x2896 9900 18500
SMG-2063 2063 1650 1875 1500 S16R-PTA2-C E 16V 65.4 418.0 230 5200x2260x2510 12192x2438x2896 10100 18700
SMG-2200 2200 1760 2000 1600 S16R-PTAA2-C E 16V 65.4 432.0 230 5200x2260x2510 12192x2438x2896 10000 18600

Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for InstrialStandby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for InstrialStandby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for InstrialStandby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for InstrialStandby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for InstrialStandby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial
 
Model Engine Alternator Controller Voltage Frequency
SMG2000 Mitsubishi Mecc-Alte DSE7320 400V 50HZ
 
 
  Dimension (L×W×H) Weight (KGS)
Open type 5200x2260x2510 (mm) /
Silent type T.B.D /
 
   
POWER RATING   Prime(PRP) Standby (ESP)
POWER KW 1600 1760
KVA 2000 2200
Rated Speed R.P.M 1500
Standard Voltage V 400
Available Voltage V 480/277-440/254-220/127-208/120
Power Factor Cos Phi 0.8
Ambient conditions of reference:
1000 mbar, 25ºC, 30% relative humidity. Power according to ISO 3046 normative.

Prime Power (PRP):
According to ISO 8528-1:2005, Prime power is the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output (Ppp) over 24 h of operation shall not exceed 70 % of the PRP.

Emergency Standby Power (ESP):
According to ISO 8528-1:2005, Emergency standby power is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed  70 % of the ESP

 
ENGINE   PRP STANDBY
Rated Output kW 1684  1895  
Manufacturer   Mitsubishi 
Model   S16R-PTAA2-C
No. of Cylindirs and Build   4 Cycle;16V Cylinder Diesel
Aspiration and Cooling   Turbo charged, water cooled 
Bore/Stroke mm 170X180
Compress the ratio   14.0
Cooling system   Water-cooled
Engine Speed/Frequency rpm/Hz 1500/50HZ
Coolant capacity  L 345
Displacement L 65.37
Lubricant system Capacity L 230
Battery voltage Type 24VDC
Governor type Type Electronic
Fuel Consumption Load 100% 75% 50% 25%
L/H  403 304 219 112 

ENGINE--Industrial 4 stroke cooled diesel engine complete with air,fuel and oil filters,electric starting and charging equipment,engine protection against low water level.

COOLING--Radiator and cooling fan complete with protection guards,designed to cool engine at specified output in air temperatures up to 45 ºC,radiators suitable for higher temperatures are available.Low water level protection fitted as standard.

ELECTRICAL SYSTEM--12V up to.Axial type starter motor,battery charging alternator,high capacity lead acid battery,and battery tray mounted on the generator base frame,and heavy duty interconnecting cable with terminations.

EXHAUST SYSTEM--Heavy duty industrial exhaust silencer with flexible piping

elf exciting,self regulation,screen protected,drip proof rated in accordance with IEC60034.Voltage regulation maintained within ±0.5% from no load to full load.between 0.8 lagging and unity.All standard voltages available.
 
 


Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial
Standby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for InstrialStandby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for InstrialStandby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for InstrialStandby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for InstrialStandby Power Generator 1000kVA Soundproof Automatic Diesel Electric Generator Set for Instrial
Professional diesel generator Manufacturer

*Diesel Generator open type or silent type (soundproof type)
*Generator Diesel Engine: Mitsubishi, DCEC, CCEC,WeiChai, Yangdong, SDEC,DOOSAN, DUETZ  etc.
*Generator with alternator: Mecc-Alte, Marathon, Leroy Somer etc.
*Diesel Generator Rated output: 5kVA - 2000kVA
*Rated frequency 50/60 Hz
*Rated voltage 230/400, 220/380, according to customers
*Power factor: 0.8(lag)
*Super Silent type Noise level at 7m ≤ 65DB
*Excitation Mode: (Brushless) Self-excitation and constant voltage (AVR)
*Starting system: Electric start 12V/24V
*Protection System: High water temperature protection, Engine oil alarm, Over load Protection
*Overfrequency protection, Emergency stop
*Control System: Digital Control Panel; Meter Panel


Diesel Generator Set Advantage

*50Hz@1500rpm or 60Hz@1800rpm all are available
*AVR delivers non fluctuating power
*Panel type digital control panel
*12 Volt / 24 Volt electric starter ensures easy starting
*Low oil pressure shut down system
*Low fuel cut out protection
*Low water cut out engine protection
*Enclosed structure ensures quieter operation
*Alternator (Dynamo) excitation mode brushless self excitation
*Three-phase output meets differing requirements
*Four Cylinder, four stroke, water cooled diesel engine
*8 hours running @ full load on a single tank of fuel
*Dual access doors for easy maintenance
*Optional automatic or manual transfer switches available
*ATS ( auto transfer switch for city power and generator power ) / AMF (auto mains failure) /parallel running for option
*Weatherproof and soundproof, enclosure high grade steel protected by powder coat painting and incorporate internally mounted exhaust silencers
*Noise Level (65-70dBA @ 7m)

All ratings are at sea level!!!


After-sales Service

*1 year or 1500 running hours subject to the earlier one. Free remote assitance by voice call or video call.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now